PRESSURE CONTROL VALVES
See:
* EVAPORATOR PRESSURE REGULATORS (EPRS)
* HIGH PRESSURE RELIEF VALVES (HPRV)
* PILOT-OPERATED ABSOLUTES (POAS)
* SUCTION THROTTLING VALVES (STVS)
* VALVES IN RECEIVER (VIRS)
PRESSURE SENSORS
See THERMISTORS AND PRESSURE SENSORS.
PULLEYS
PULLEY INSPECTION
Condition Code Procedure
Alignment incorrect ..... B .. Require repair or replacement.
Application incorrect ... B ............ Require replacement.
Attaching hardware
broken ................. A ... Require repair or replacement
of hardware.
Attaching hardware
missing ................ C .......... Require replacement of
hardware.
Attaching hardware not
functioning ............ A ... Require repair or replacement
of hardware.
Bearing noisy ........... 2 ............ Suggest replacement.
Bearing seized .......... A .. Require repair or replacement.
Bearing worn ............ 1 ............ Suggest replacement.
Cracked ................. A ............ Require replacement.
Loose ................... A .. Require repair or replacement.
Missing ................. C ............ Require replacement.
Pulley damaged, affecting
belt life .............. A ............ Require replacement.
RADIATORS
RADIATOR INSPECTION
Condition Code Procedure
Air flow obstruction .... A ................. Require repair.
Application incorrect ... B ............ Require replacement.
Attaching hardware
broken ................. A ... Require repair or replacement
of hardware.
Attaching hardware
missing ................ C .......... Require replacement of
hardware.
Attaching hardware not
functioning ............ A .. Require repair or replacement
of hardware.
Connection leaking ...... A .. Require repair or replacement.
Corroded ................ 1 .. Suggest repair or replacement.
Drain inoperative ....... A .. Require repair or replacement.
Fins damaged, affecting
performance ............ A .. Require repair or replacement.
Fins damaged, not
affecting performance .. .. ........ No service suggested or
required.
Internal oil cooler
leaking ................ A .. Require repair or replacement.
Internal restrictions ... B .. Require repair or replacement.
Leaking ................. A .. Require repair or replacement.
Threads damaged ......... A .. Require repair or replacement.
Threads stripped (threads
missing) ............... A .. Require repair or replacement.
Tubes damaged, affecting
performance ............ A .. Require repair or replacement.
Tubes damaged, not
affecting performance .. .. ........ No service suggested or
required.
RECEIVER-DRIERS
NOTE: For VIRs, see VALVES IN RECEIVER (VIRS).
RECEIVER-DRIER INSPECTION
Condition Code Procedure
Attaching hardware
broken ................. A ... Require repair or replacement
of hardware.
Attaching hardware
missing ................ C .......... Require replacement of
hardware.
Attaching hardware not
functioning ............ A ... Require repair or replacement
of hardware.
Contaminated, affecting
performance ............ A ............ Require replacement.
Dessicant bag
deteriorated ........... A ........ (1) Require replacement.
Further inspection required.
Dessicant at the end of
its useful life (saturated
with moisture) ......... 1 .. Suggest repair or replacement.
Fusible plug leaking .... A .... Require replacement of plug.
Leaking ................. A ............ Require replacement.
Pressure relief device
leaking ................ A . Require replacement of pressure
relief device.
Restricted .............. A .. Require repair or replacement.
Sight glass no longer
transparent ............ 2 ... Suggest replacement of drier.
Threads damaged ......... A .. Require repair or replacement.
Threads stripped (threads
missing) ............... A ............ Require replacement.
Tubing connection
leaking ................ A .. Require repair or replacement.
(1) - Inspect system to determine effects of dessicant bag
deterioration.
REFRIGERANT
NOTE: Refrigerants include any SNAP (Significant New Alternative
Policy)-approved blends.
REFRIGERANT INSPECTION
Condition Code Procedure
Contaminated (other than
refrigerant blends) .... B ........ Require service to remove
contamination.
Different types of
refrigerants in the same
system (other than
refrigerant blends) .... B ................. Require repair.
Overcharged ............. B ................. Require repair.
Refrigerant type
does not match
fittings and label ..... B ................. Require repair.
Undercharged ............ B ................. Require repair.
REFRIGERANT OIL
REFRIGERANT OIL INSPECTION
Condition Code Procedure
Contaminated ............ 1 .. Require repair or replacement.
Overfilled .............. B ................. Require repair.
Underfilled ............. B ................. Require repair.
RELAYS
RELAY INSPECTION
Condition Code Procedure
Attaching hardware
broken ................. A ... Require repair or replacement
of hardware.
Attaching hardware
missing ................ C .......... Require replacement of
hardware.
Attaching hardware not
functioning ............ A ... Require repair or replacement
of hardware.
Housing broken .......... A ............ Require replacement.
Housing cracked ......... 2 ............ Suggest replacement.
Inoperative ............. A ........ (1) Require replacement.
Melted, affecting
performance ............ A ........... (2) Require repair or
replacement.
Melted, not affecting
performance ............ 2 ........... (2) Suggest repair or
replacement.
Missing ................. C ............ Require replacement.
Terminal broken ......... A .. Require repair or replacement.
Terminal burned, affecting
performance ............ A ........... (2) Require repair or
replacement.
Terminal burned, not
affecting performance .. 2 .. Suggest repair or replacement.
Terminal corroded,
affecting performance .. A .. Require repair or replacement.
Terminal corroded, not
affecting performance .. 2 .. Suggest repair or replacement.
Terminal loose, affecting
performance ............ B .. Require repair or replacement.
Terminal loose, not
affecting performance .. 1 .. Suggest repair or replacement.
(1) - Inoperative includes intermittent operation or out of
OEM specification.
(2) - Determine cause and correct prior to repair or
replacement of part.
SEALS
SEAL INSPECTION
Condition Code Procedure
Leaking ................. A ........... (1) Require repair or
replacement.
(1) - Require inspection of mating and sealing surface and
repair or replace as necessary.
SERVICE PORTS
SERVICE PORT INSPECTION
Condition Code Procedure
Application
does not match
refrigerant type ....... B ............ Require replacement.
Leaking ................. A .. Require repair or replacement.
Threads damaged ......... A .. Require repair or replacement.
Threads stripped (threads
missing) ............... A ............ Require replacement.
Valve cap leaking ....... A ... Require repair or replacement
of cap.
Valve cap missing ....... C .... Require replacement of valve
cap.
Valve core sticking ..... B .. Require repair or replacement.
SPRING LOCK COUPLINGS
SPRING LOCK COUPLING INSPECTION
Condition Code Procedure
Leaking ................. A ........... (1) Require repair or
replacement.
(1) - Require inspection of mating and sealing surface and
repair or replace as necessary.
SUCTION THROTTLING VALVES (STVS)
SUCTION THROTTLING VALVE (STV) INSPECTION
Condition Code Procedure
Connection damaged ...... B .. Require repair or replacement.
Fitting damaged ......... B .. Require repair or replacement.
Inoperative ............. A ........... (1) Require repair or
replacement.
Leaking ................. A .. Require repair or replacement.
Threads damaged ......... A .. Require repair or replacement.
Threads stripped (threads
missing) ............... A ............ Require replacement.
(1) - Inoperative includes intermittent operation or out of
OEM specification.